Receiver sensitivity measurement

The receiver sensitivity measurement determines the lowest possible power (MDS, Minimum Detectable Signal, or Minimum Discernible Signal) at the input of a receiver at which the radar can still detect a target. This measurement provides an important indication of the performance of a radar.

Measurement on analog receivers

The prerequisite for such a measurement is a calibrated RF signal generator, which may also be capable of providing special modulation types. You will need an oscilloscope and a variable attenuator as a further aid.

With the help of a suitable RF signal generator, RF pulses are generated in the rhythm of the pulse repetition frequency, which has a power of 1 mW (= 0 dBm). These pulses are fed into the receive path via a variable attenuator. The receiver video is fed to an oscilloscope. With the help of the variable attenuator, the RF signals are now attenuated until the amplitude of the received signal on the oscilloscope is 3 dB (!) above the noise floor. But be careful! The 3 dB refers to a power level. However, the oscilloscope does not indicate power, but a voltage! One might now think that doubling the power (3 dB) would require a quadrupling of the amplitude (6 dB). In principle: Yes, but here only relative amplitudes are measured in comparison to each other. The level of the noise signal is also only evaluated by its amplitude on the oscilloscope. A doubling of the factor of 0.707 is nevertheless 2 × 0.707. The variable attenuator is therefore adjusted until a signal-to-noise ratio of the amplitudes of about 2 to 1 is obtained. The attenuations of the test setup (cables, connectors, directional couplers) are added to the value readable from the variable attenuator. The result gives the MDS value for the measured receiver.

to antenna
RF- Pulse
generator
 0 dBm
variable
attenuator
0 … −120 dB
direct.
coupler
−31.5dB
Duplexer
Receiver
under test
Transmitter
Syncronizer
−0,5 dB
−5 dB calibrated line
−0,5 dB loss in plug connector

Figure 2: Measurement Setup for MDS, including attenuation from the directional coupler, plug connectors, and cable

to antenna
Transmitter
Syncronizer
−0,5 dB
−5 dB calibrated line
−0,5 dB loss in plug connector

Figure 2: Measurement Setup for MDS, including attenuation from the directional coupler, plug connectors, and cable

to antenna
Transmitter
Syncronizer
−0,5 dB
−5 dB calibrated line
−0,5 dB loss in plug connector

Figure 2: Measurement Setup for MDS, including attenuation from the directional coupler, plug connectors, and cable (interactive picture)

In this example setup, the attenuation measured by the calibration lab — accounting for the two connectors — is added to the value read (e.g., −100 dB). This results in only −106 dBm reaching the receiver input. Since the noise floor visible on the oscilloscope during the MDS measurement fluctuates, precise measurement can be challenging. To minimize the tolerance range of the measurement, the noise signal should be optically averaged, then numerically evaluated. The attenuation is adjusted until the test signal’s amplitude doubles this value.

Measurement on digital receivers

In digital radars, receiver sensitivity can be tested using an internal routine that runs during the radar's dead time — that is, when the phase shifters of a phased array antenna are retuned for a new radiation direction. This internal test mimics the measurement procedure in an analog radar.

External measurements generally only take place under workshop conditions. These require multiple instruments capable of simulating the transmitter’s signals at any moment, synchronized with the radar. This setup allows the original waveform to be delayed as needed to display it at the desired distance, outside the range of the sensitivity time control (STC).

With active phased array antennas, this procedure must be performed on each single transmit/receive module. This can be done under laboratory conditions during maintenance or under operating conditions as part of a built-in test routine (BITE). During this measurement, however, it must be noted that the sensitivity of a single receiver must be significantly worse than the sensitivity of the overall system. This is because the echo signals are all coherently summed, but the noise is non-coherent and therefore cannot be summed to the same extent.