www.radartutorial.eu www.radartutorial.eu Radar Basics

Palmer Scan

Figure 1: Principle of the Palmer raster method with two lines

Figure 1: Principle of the Palmer raster method with two lines

Palmer Scan

A Palmer Scan is a sequence of space scanning that results from the combination of the rapid antenna pattern rotation at a conical scan with any other linear or circular motion pattern. Depending on the superior motion pattern, a distinction is made between:

In the graphic, the red curve describes the movement of the radiated energy maximum, and the blue rectangular curve the movement of the central antenna axis („boresight“).

If a conical scan is achieved using a rotating primary radiation source, the polarization — typically linear — will also rotate. Alternatively, a conical scan can be performed with a rotating auxiliary reflector. In this situation, the linear polarization remains constant, or it may be even switched to circular polarization.

Palmer scans were utilized in older tracking radars for target search before the development of simultaneous target search and tracking capabilities, known as track-while-scan. The advantage of this method was that it did not require additional switching mechanisms to deactivate the conical scan during target search. However, the drawback was that it resulted in very uneven spatial scanning. With the advent of phased arrays and monopulse antennas, this technology has largely become obsolete. Today, only optical sensors using lasers in connection with nutating mirors still employ such scanning patterns.