Measuring the phase noise
Figure 1: R&S®FSPN phase noise analyzer and VCO tester
(Courtesy of Rohde & Schwarz)
Measuring the phase noise
Determining the phase noise or jitter of signal generators such as frequency synthesizers, VCOs, OCXOs or DROs is best done through direct measurement with a spectrum analyzer. The phase noise inevitably increases the spectrum of the oscillator and so the phase noise can be measured from the steepness of the edge of the signal. However, the phase noise of the internal oscillators of the spectrum analyzer must be low enough so that it does not interfere with the properties of the measurement object. Keep in mind that the measurement will not only display the phase noise of the DUT (device under test), but also the power of the phase noise of the internal oscillators as well as thermal noise.
Figure 1: Messaufbau
To address this issue, special measuring stations provide a particularly stabilized operating voltage for the oscillator being measured. This allows the user to obtain a calibration curve for the tuning voltage, which can be used to achieve the most linear tuning possible through a digital-to-analog converter. This is especially important for Frequency-Modulated Continuous-Wave Radar.