AN/TPQ-10
Description of the radar set, tactical-technical characteristics
Figure 1: AN/TPQ-10
Hersteller:General Electric
| Specifications | |
|---|---|
| frequency: | 8 500 … 9 600 MHz
(X band) |
| pulse repetition time (PRT): | |
| pulse repetition frequency (PRF): | 700 Hz |
| pulsewidth (τ): | 0.5 µs |
| receiving time: | |
| dead time: | |
| peak power: | 250 kW |
| average power: | |
| instrumented range: | 200 km |
| range resolution: | |
| accuracy: | |
| beamwidth: | 1.2° |
| hits per scan: | |
| antenna rotation: | |
| MTBCF: | |
| MTTR: | |
AN/TPQ-10
AN/TPQ-10 is operating in the X band (IEEE designation) or in the I band (NATO designation) target tracking radar. The TPQ-10 was the last ground directed bombing radar ever fielded. It replaced the outdated AN/MPQ-14 and was made later obsolete by the GPS guided bombs.